Division Emission levels associated with the best available techniques (BAT-AELs) for emissions to air

United Kingdom

Original text. Later amendments are not shown.

Emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to concentrations, expressed as mass of emitted substances per volume of flue-gas or of extracted air under the following standard conditions: dry gas at a temperature of 273,15 K and a pressure of 101,3 kPa, and expressed in mg/Nm3, µg/Nm3, ng I-TEQ/Nm3 or ng WHO-TEQ/Nm3.

The reference oxygen levels used to express BAT-AELs in this document are shown in the table below.

ActivityReference oxygen level (OR)
Incineration of waste11 dry vol-%
Bottom ash treatmentNo correction for the oxygen level

The equation for calculating the emission concentration at the reference oxygen level is:

Where:

ER
  • emission concentration at the reference oxygen level OR;

  • OR
  • reference oxygen level in vol-%;

  • EM
  • measured emission concentration;

  • OM
  • measured oxygen level in vol-%.

  • For averaging periods, the following definitions apply:

    For any parameter where, due to sampling or analytical limitations, 30-minute sampling/measurement and/or an average of three consecutive measurements is inappropriate, a more suitable procedure may be employed. For PCDD/F and dioxin-like PCBs, one sampling period of 6 to 8 hours is used in the case of short-term sampling.

    Type of measurementAveraging periodDefinition
    ContinuousHalf-hourly averageAverage value over a period of 30 minutes
    Daily averageAverage over a period of one day based on valid half-hourly averages
    PeriodicAverage over the sampling periodAverage value of three consecutive measurements of at least 30 minutes eachf1
    Long-term sampling periodValue over a sampling period of 2 to 4 weeks

    When waste is co-incinerated together with non-waste fuels, the BAT-AELs for emissions to air given in these BAT conclusions apply to the entire flue-gas volume generated.

    Annotations

    Footnotes

    f1

    For any parameter where, due to sampling or analytical limitations, 30-minute sampling/measurement and/or an average of three consecutive measurements is inappropriate, a more suitable procedure may be employed. For PCDD/F and dioxin-like PCBs, one sampling period of 6 to 8 hours is used in the case of short-term sampling.