Division Explanatory note to Table 3
United Kingdom
The applied fixed upper limit (13 dBm/(5 MHz) for non-AAS or 1 dBm/(5 MHz) for AAS) provides an upper bound on the interference from a base station. When two TDD blocks are synchronised, there will be no interference between base stations.
Notes on Division Figure
Footnotes
- f1
-
PMax is the maximum mean carrier power in dBm for the base station measured as e.i.r.p. per carrier per antenna
- f2
-
PMax′ is the maximum mean carrier power in dBm for the base station measured as TRP per carrier in a given cell
- f3
-
In a multi-sector base station, the radiated power limit applies to each one of the individual sectors.
- f4
-
PMax is the maximum mean carrier power in dBm for the base station measured as e.i.r.p. per carrier per antenna
- f5
-
PMax′ is the maximum mean carrier power in dBm for the base station measured as TRP per carrier in a given cell
- f6
-
In a multi-sector base station, the radiated power limit applies to each one of the individual sectors.
- f7
-
In a multi-sector base station, the radiated power limit applies to each one of the individual sectors.
- f8
-
Alternative measures may be required on a case by case basis for indoor AAS base stations on a national basis.
- f9
-
In cases where Member States have already implemented a guard band when issuing licences for terrestrial systems capable of providing WBB ECS before the adoption of this Decision and in accordance with Commission Decision 2008/411/EC, those Member States may apply the additional baseline only below such guard band, provided it complies with the protection of radars in the adjacent band and with cross-border obligations.
- f10
-
In a multi-sector base station, the radiated power limit applies to each one of the individual sectors
- f11
-
PMax is the maximum mean carrier power in dBm for the base station measured as e.i.r.p. per carrier per antenna
- f12
-
PMax′ is the maximum mean carrier power in dBm for the base station measured as TRP per carrier in a given cell
- f13
-
In a multi-sector base station, the radiated power limit refers to the level corresponding to each one of the individual sectors