Division 4.3 Saved mechanical power
United Kingdom
The 48 V motor generator plus the 48V/12V DC/DC converter generation function lead to saved mechanical power under real-world conditions (ΔPmRW) and type approval conditions (ΔPmTA) as set out in Formula 14.
Formula 14
ΔPm = ΔPmRW – ΔPmTA
Where the saved mechanical power under real-world conditions (ΔPmRW) shall be calculated in accordance with Formula 15 and the saved mechanical power under type-approval conditions (ΔPmTA) in accordance with Formula 16:
-
Formula 15
-
Formula 16
where
Power requirement under ‘real-world’ conditions [W], which is estimated at 750W
Power requirement under type-approval NEDC conditions [W], which is estimated at 350W
Efficiency of the baseline alternator [%], which is 67 %