OpenLegislation

Division 4.3 Saved mechanical power

United Kingdom

Original text. Later amendments are not shown.

The 48 V motor generator plus the 48V/12V DC/DC converter generation function lead to saved mechanical power under real-world conditions (ΔPmRW) and type approval conditions (ΔPmTA) as set out in Formula 14.

Formula 14

ΔPm = ΔPmRW – ΔPmTA

Where the saved mechanical power under real-world conditions (ΔPmRW) shall be calculated in accordance with Formula 15 and the saved mechanical power under type-approval conditions (ΔPmTA) in accordance with Formula 16:

  • Formula 15

    ΔP mRW = P RW η B − P RW η TOT
  • Formula 16

    ΔP mTA = P TA η B − P TA η TOT

where

PRW
  • Power requirement under ‘real-world’ conditions [W], which is estimated at 750W

  • PTA
  • Power requirement under type-approval NEDC conditions [W], which is estimated at 350W

  • ηB
  • Efficiency of the baseline alternator [%], which is 67 %