Division 3.4 Calculation of the CO2 savings
United Kingdom
The CO2 savings of the 48 V motor generator plus the 48V/12V DC/DC converter shall be calculated in accordance with Formula 7:
Formula 7
Where:
v VPe
CF
Mean driving speed of the NEDC [km/h], which is 33,58 km/h
Consumption of effective power specified in Table 2:
Table 2
Consumption of effective power
| Type of engine | Consumption of effective power (VPe)[l/kWh] |
|---|---|
| Petrol | 0,264 |
| Petrol Turbo | 0,280 |
| Diesel | 0,220 |
Conversion factor (l/100 km) - (g CO2/km) [gCO2/l] as defined in Table 3
Table 3
Fuel conversion factor
| Type of fuel | Conversion factor (l/100 km) - (g CO2/km) (CF)[gCO2/l] |
|---|---|
| Petrol | 2 330 |
| Diesel | 2 640 |