OpenLegislation

Division 3.4 Calculation of the CO2 savings

United Kingdom

Original text. Later amendments are not shown.

The CO2 savings of the 48 V motor generator plus the 48V/12V DC/DC converter shall be calculated in accordance with Formula 7:

Formula 7

C CO 2 = ΔP m × V Pe × CF v

Where:

v
  • Mean driving speed of the NEDC [km/h], which is 33,58 km/h

  • VPe
  • Consumption of effective power specified in Table 2:

    Table 2

    Consumption of effective power

    Type of engineConsumption of effective power (VPe)[l/kWh]
    Petrol0,264
    Petrol Turbo0,280
    Diesel0,220
  • CF
  • Conversion factor (l/100 km) - (g CO2/km) [gCO2/l] as defined in Table 3

    Table 3

    Fuel conversion factor

    Type of fuelConversion factor (l/100 km) - (g CO2/km) (CF)[gCO2/l]
    Petrol2 330
    Diesel2 640