Division 2 LOCATION TRACKING SYSTEMS Type 1 (LT1)
United Kingdom
| The DAA mitigation technique and its limits are defined in clauses 4.5.1.1, 4.5.1.2 and 4.5.1.3 of ETSI Standard EN 302 065-2 V2.1.1. Alternative mitigation techniques may be used if they ensure at least an equivalent performance and level of spectrum protection in order to comply with the corresponding essential requirements of Directive 2014/53/EU and respect the technical requirements of this Decision. | ||
| Technical requirements | ||
|---|---|---|
| Frequency range | Maximum mean power spectral density (e.i.r.p.) | Maximum peak power (e.i.r.p.)(defined in 50 MHz) |
| f ≤ 1,6 GHz | – 90 dBm/MHz | – 50 dBm |
| 1,6 < f ≤ 2,7 GHz | – 85 dBm/MHz | – 45 dBm |
| 2,7 < f ≤ 3,4 GHz | – 70 dBm/MHz | – 36 dBm |
| 3,4 < f ≤ 3,8 GHz | – 80 dBm/MHz | – 40 dBm |
| 3,8 < f ≤ 6,0 GHz | – 70 dBm/MHz | – 30 dBm |
| 6 < f ≤ 8,5 GHz | – 41,3 dBm/MHz | 0 dBm |
| 8,5 < f ≤ 9 GHz | – 65 dBm/MHz or – 41,3 dBm/MHz using DAAf1 | – 25 dBm or 0 dBm |
| 9 < f ≤ 10,6 GHz | – 65 dBm/MHz | – 25 dBm |
| f > 10,6 GHz | – 85 dBm/MHz | – 45 dBm |
Annotations
Footnotes
- f1
-
The DAA mitigation technique and its limits are defined in clauses 4.5.1.1, 4.5.1.2 and 4.5.1.3 of ETSI Standard EN 302 065-2 V2.1.1. Alternative mitigation techniques may be used if they ensure at least an equivalent performance and level of spectrum protection in order to comply with the corresponding essential requirements of Directive 2014/53/EU and respect the technical requirements of this Decision.