{
  "url": "https://openlegislation.uk/eu-decision-2019-785/annex/division-5/division-5.1",
  "json_url": "https://openlegislation.uk/eu-decision-2019-785/annex/division-5/division-5.1.json",
  "legislation": "eudn/2019/785",
  "legislation_title": "Commission Implementing Decision (EU) 2019/785 of 14 May 2019 on the harmonisation of radio spectrum for equipment using ultra-wideband technology in the Union and repealing Decision 2007/131/EC (notified under document C(2019) 3461) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2019-785",
  "path": "annex/division/5/division/5.1",
  "kind": "division",
  "number": "5.1",
  "heading": "Introduction",
  "text": "UWB material sensing devices are split into two classes:\nContact based UWB material sensing devices, for which the UWB transmitter is only switched on when in direct contact with the material under investigation;\nNon-contact based UWB material sensing devices, for which the UWB transmitter is only switched on when it is near the investigated material and the UWB transmitter is directed towards the material under investigation (for example manually by using a proximity sensor or by mechanical design).\nMaterial sensing devices based on UWB technology shall comply either with the generic UWB regulation based on technical conditions specified in section 1 of this Annex or with the specific limits for material sensing devices as defined in sections 5.2 and 5.3.\nThe generic UWB regulation excludes fixed outdoor installations. Emissions radiated by a material sensing device must not exceed the limits of the regulation for generic UWB usage specified in section 1. Material sensing devices must fulfil the requirements of mitigation techniques specified for the generic use of UWB in section 1.\nThe specific limits for material sensing devices including the mitigation techniques are listed in the following tables. Emissions radiating from material sensing devices permitted under this Decision must be kept to a minimum and in any case not exceed the emission limits within the following tables. Compliance with the specific limits must be ensured by the device placed on a representative structure of the investigated material. The specific limits listed in the following tables are applicable in all environments for material sensing devices, except those to which note 5 of these tables, which excludes fixed outdoor installation in certain applicable frequency ranges, applies.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2019/785/annex/division/5/division/5.1",
    "retrieved_at": "2026-11-01T15:12:42.568808+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}