Division 2.1 48V motor-generator efficiency
United Kingdom
The efficiency of the 48V motor-generator shall be determined in accordance with ISO 8854:2012, with the following precisions.
The manufacturer shall provide evidence to the type-approval authority that the frequency ranges of the 48V motor-generator are the same as or equivalent to those set out in Table 1.
The efficiency of the 48V motor-generator shall be determined on the basis of measurements at each of the operating points listed in Table 1.
The current intensity of the 48V motor-generator at each operating point shall be half the rated current. For each operating point, the voltage and the output current of the 48V motor-generator shall be kept constant during the measurement, with the voltage at 52V.
Table 1
| Operating pointi | Holding time[s] | Rotational frequency | Frequency of operating points |
|---|---|---|---|
| 1 | 1 200 | 1 800 | 0,25 |
| 2 | 1 200 | 3 000 | 0,40 |
| 3 | 600 | 6 000 | 0,25 |
| 4 | 300 | 10 000 | 0,10 |
The efficiency of the 48V motor-generator at each operating point i ( ) [%] shall be calculated in accordance with Formula 1.
Formula 1
where, for each operating point i,
is the voltage [V];
is the current intensity [A];
is the torque [Nm];
is the rotational frequency [min-1].
For each operating point, the measurements are to be performed at least five times consecutively and the efficiency shall be calculated for each of those measurements with j being the index referring to one set of measurements.
For each operating point, the average of those efficiencies shall be calculated.
The efficiency of the 48V motor-generator [%] shall be calculated in accordance with Formula 2.
Formula 2
where
is the mean efficiency of the 48V motor-generator determined for operating point i [%]
is the frequency of operating point i, as set out in Table 1.