Division 2 DETERMINATION OF THE EFFICIENCY OF THE 12V MOTOR GENERATOR

United Kingdom

Original text. Later amendments are not shown.

The efficiency of the 12V motor-generator shall be determined in accordance with ISO 8854:2012, with the following precisions.

The manufacturer shall provide evidence to the F1Secretary of State that the frequency ranges of the 12V motor-generator are the same as or equivalent to those set out in Table 1.

The efficiency of the 12V motor-generator shall be determined on the basis of measurements at each of the operating points listed in Table 1.

The current intensity of the 12V motor-generator at each operating point shall be half the rated current. For each operating point, the voltage and the output current of the 12V motor-generator shall be kept constant during the measurement, with the voltage at 14,3 V.

Table 1

Operating pointiHolding time[s]Rotational frequencyni [min–1]Frequency of operating pointshi
11 2001 8000,25
21 2003 0000,40
36006 0000,25
430010 0000,10

The efficiency of the 12V motor-generator at each operating point i () [%] shall be calculated in accordance with Formula 1.

  1. Formula 1
  2. Formula 2