Division BAT 17 In order to reduce NOX emissions in waste gases while limiting CO emissions from the thermal treatment of solvents in off-gases, BAT is to use technique (a) or both of the techniques given below.
United Kingdom
| Technique | Description | Applicability | |
|---|---|---|---|
| (a) | Optimisation of thermal treatment conditions (design and operation) | Good design of the combustion chambers, burners and associated equipment/devices is combined with optimisation of combustion conditions (e.g. by controlling combustion parameters such as temperature and residence time) with or without the use of automatic systems and the regular planned maintenance of the combustion system according to suppliers’ recommendations. | Design applicability may be restricted for existing plants. |
| (b) | Use of low-NOX burners | The peak flame temperature in the combustion chamber is reduced, delaying but completing the combustion and increasing the heat transfer (increased emissivity of the flame). It is combined with increased residence time in order to achieve the desired VOC destruction. | Applicability may be restricted at existing plants by design and/or operational constraints. |
Table 1
BAT-associated emission level (BAT-AEL) for NOX emissions in waste gases and indicative emission level for CO emissions in waste gases from the thermal treatment of off-gases
| The BAT-AEL and indicative level do not apply where off-gases are sent to a combustion plant. | |||
| The BAT-AEL may not apply if nitrogen-containing compounds (e.g. DMF or NMP (N-methylpyrrolidone)) are present in the off-gas. | |||
| Parameter | Unit | BAT-AELf1(Daily average or average over the sampling period) | Indicative emission level(Daily average or average over the sampling period) |
|---|---|---|---|
| NOX | mg/Nm3 | 20–130f2 | No indicative level |
| CO | No BAT-AEL | 20–150 | |
The associated monitoring is given in BAT 11.
Annotations
Footnotes
- f1
-
The BAT-AEL and indicative level do not apply where off-gases are sent to a combustion plant.
- f2
-
The BAT-AEL may not apply if nitrogen-containing compounds (e.g. DMF or NMP (N-methylpyrrolidone)) are present in the off-gas.