# Commission Implementing Decision (EU) 2020/2009 of 22 June 2020 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for surface treatment using organic solvents including preservation of wood and wood products with chemicals (notified under document C(2020) 4050) (Text with EEA relevance), Division BAT 10: BAT is to monitor total and fugitive VOC emissions by compiling, at least once every year, a solvent mass balance of the solvent inputs and outputs of the plant, as defined in Part 7(2) of Annex VII to Directive 2010/75/EU and to minimise the uncertainty of the solvent mass balance data by using all of the techniques given below.

Extent: E+W+S+N.I.

Technique
Description
(a)
Full identification and quantification of the relevant solvent inputs and outputs, including the associated uncertainty
This includes:
identification and documentation of solvent inputs and outputs (e.g. emissions in waste gases, emissions from each fugitive emission source, solvent output in waste);
substantiated quantification of each relevant solvent input and output and recording of the methodology used (e.g. measurement, calculation using emission factors, estimation based on operational parameters);
identification of the main sources of uncertainty of the aforementioned quantification, and implementation of corrective actions to reduce the uncertainty;
regular update of solvent input and output data.
(b)
Implementation of a solvent tracking system
A solvent tracking system aims to keep control of both the used and unused quantities of solvents (e.g. by weighing unused quantities returned to storage from the application area).
(c)
Monitoring of changes that may influence the uncertainty of the solvent mass balance data
Any change that could influence the uncertainty of the solvent mass balance data is recorded, such as:
malfunctions of the off-gas treatment system: the date and duration are recorded;
changes that may influence air/gas flow rates, e.g. replacement of fans, drive pulleys, motors; the date and type of change are recorded.
Applicability
The level of detail of the solvent mass balance will be proportionate to the nature, scale and complexity of the installation, and the range of environmental impacts it may have, as well as to the type and quantity of materials used.

---
Source: https://www.legislation.gov.uk/eudn/2020/2009/annex/division/1/division/1.1/division/1.1.9/division/1.1.9.1/division/BAT (the official version)
Page: https://openlegislation.uk/eu-decision-2020-2009/annex/division-1/division-1.1/division-1.1.9/division-1.1.9.1/division-BAT
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.