  "legislation_title": "Commission Implementing Decision (EU) 2020/2009 of 22 June 2020 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for surface treatment using organic solvents including preservation of wood and wood products with chemicals (notified under document C(2020) 4050) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2020-2009",
  "path": "annex/division/1/division/1.1/division/1.1.9/division/1.1.9.2/division/BAT",
  "kind": "division",
  "number": "BAT 11",
  "heading": "BAT is to monitor emissions in waste gases with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.",
  "text": "To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions.\nIn the case of a TVOC load of less than 0,1 kg C/h, or in the case of an unabated and stable TVOC load of less than 0,3 kg C/h, the monitoring frequency may be reduced to once every 3 years or the measurement may be replaced by calculation provided that it ensures the provision of data of an equivalent scientific quality.\nFor the thermal treatment of off-gases, the temperature in the combustion chamber is continuously measured. This is combined with an alarm system for temperatures falling outside the optimised temperature window.\nGeneric EN standards for continuous measurements are EN15267-1, EN15267-2, EN15267-3 and EN 14181.\nThe monitoring only applies if DMF is used in the processes.\nIn the absence of an EN standard, the measurement includes the DMF contained in the condensed phase.\nIn the case of a stack with a TVOC load of less than 0,1 kg C/h, the monitoring frequency may be reduced to once every 3 years.\nSubstance/Parameter\nSectors/Sources\nStandard(s)\nMinimum monitoring frequency\nMonitoring associated with\nDust\nCoating of vehicles – Spray coating\nEN 13284-1\nOnce every year\nBAT 18\nCoating of other metal and plastic surfaces – Spray coating\nCoating of aircraft – Preparation (e.g. sanding, blasting) and coating\nCoating and printing of metal packaging – Spray application\nCoating of wooden surfaces – Preparation and coating\nTVOC\nAll sectors\nAny stack with a TVOC load < 10 kg C/h\nEN 12619\nOnce every year\nBAT 14, BAT 15\nAny stack with a TVOC load ≥ 10 kg C/h\nGeneric EN standards\nContinuous\nDMF\nCoating of textiles, foils and paper\nNo EN standard available\nOnce every three months\nBAT 15\nNOX\nThermal treatment of off-gases\nEN 14792\nOnce every year\nBAT 17\nCO\nThermal treatment of off-gases\nEN 15058\nOnce every year\nBAT 17",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "In the case of a TVOC load of less than 0,1 kg C/h, or in the case of an unabated and stable TVOC load of less than 0,3 kg C/h, the monitoring frequency may be reduced to once every 3 years or the measurement may be replaced by calculation provided that it ensures the provision of data of an equivalent scientific quality."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "For the thermal treatment of off-gases, the temperature in the combustion chamber is continuously measured. This is combined with an alarm system for temperatures falling outside the optimised temperature window."
    },
    {
      "type": "footnote",
      "label": "f4",
      "text": "Generic EN standards for continuous measurements are EN15267-1, EN15267-2, EN15267-3 and EN 14181."
    },
    {
      "type": "footnote",
      "label": "f5",
      "text": "The monitoring only applies if DMF is used in the processes."
    },
    {
      "type": "footnote",
      "label": "f6",
      "text": "In the absence of an EN standard, the measurement includes the DMF contained in the condensed phase."
    },
    {
      "type": "footnote",
      "label": "f7",
      "text": "In the case of a stack with a TVOC load of less than 0,1 kg C/h, the monitoring frequency may be reduced to once every 3 years."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2020/2009/annex/division/1/division/1.1/division/1.1.9/division/1.1.9.2/division/BAT",
    "retrieved_at": "2026-11-01T15:12:03.527850+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}