  "url": "https://openlegislation.uk/eu-decision-2020-2009/annex/division-1/division-1.1/division-1.1.9/division-1.1.9.3/division-BAT",
  "json_url": "https://openlegislation.uk/eu-decision-2020-2009/annex/division-1/division-1.1/division-1.1.9/division-1.1.9.3/division-BAT.json",
  "legislation": "eudn/2020/2009",
  "legislation_title": "Commission Implementing Decision (EU) 2020/2009 of 22 June 2020 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for surface treatment using organic solvents including preservation of wood and wood products with chemicals (notified under document C(2020) 4050) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2020-2009",
  "path": "annex/division/1/division/1.1/division/1.1.9/division/1.1.9.3/division/BAT",
  "kind": "division",
  "number": "BAT 12",
  "heading": "BAT is to monitor emissions to water with at least the frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.",
  "text": "The monitoring only applies in the case of direct discharge to a receiving water body.\nThe monitoring frequency may be reduced to once every 3 months if the emission levels are proven to be sufficiently stable.\nIn the case of batch discharge that is less frequent than the minimum monitoring frequency, monitoring is carried out once per batch.\nTOC monitoring and COD monitoring are alternatives. TOC monitoring is the preferred option because it does not rely on the use of very toxic compounds.\nMonitoring of Cr(VI) only applies if chromium(VI) compounds are used in the processes.\nIn the case of indirect discharge to a receiving water body, the monitoring frequency may be reduced if the downstream waste water treatment plant is designed and equipped appropriately to abate the pollutants concerned.\nMonitoring of Cr only applies if chromium compounds are used in the processes.\nMonitoring of F- only applies if fluorine compounds are used in the processes.\nSubstance/Parameter\nSector\nStandard(s)\nMinimum monitoring frequency\nMonitoring associated with\nTSS\nCoating of vehicles\nEN 872\nOnce every month\nBAT 21\nCoil coating\nCoating and printing of metal packaging (only for DWI cans)\nCOD\nCoating of vehicles\nNo EN standard available\nCoil coating\nCoating and printing of metal packaging (only for DWI cans)\nTOC\nCoating of vehicles\nEN 1484\nCoil coating\nCoating and printing of metal packaging (only for DWI cans)\nCr(VI)\nCoating of aircraft\nEN ISO 10304-3 or EN ISO 23913\nCoil coating\nCr\nCoating of aircraft\nVarious EN standards available (e.g. EN ISO 11885, EN ISO 17294-2, EN ISO 15586)\nCoil coating\nNi\nCoating of vehicles\nCoil coating\nZn\nCoating of vehicles\nCoil coating\nAOX\nCoating of vehicles\nEN ISO 9562\nCoil coating\nCoating and printing of metal packaging (only for DWI cans)\nF-\nCoating of vehicles\nEN ISO 10304-1\nCoil coating\nCoating and printing of metal packaging (only for DWI cans)",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "The monitoring only applies in the case of direct discharge to a receiving water body."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "The monitoring frequency may be reduced to once every 3 months if the emission levels are proven to be sufficiently stable."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "In the case of batch discharge that is less frequent than the minimum monitoring frequency, monitoring is carried out once per batch."
    },
    {
      "type": "footnote",
      "label": "f4",
      "text": "TOC monitoring and COD monitoring are alternatives. TOC monitoring is the preferred option because it does not rely on the use of very toxic compounds."
    },
    {
      "type": "footnote",
      "label": "f5",
      "text": "Monitoring of Cr(VI) only applies if chromium(VI) compounds are used in the processes."
    },
    {
      "type": "footnote",
      "label": "f6",
      "text": "In the case of indirect discharge to a receiving water body, the monitoring frequency may be reduced if the downstream waste water treatment plant is designed and equipped appropriately to abate the pollutants concerned."
    },
    {
      "type": "footnote",
      "label": "f7",
      "text": "Monitoring of Cr only applies if chromium compounds are used in the processes."
    },
    {
      "type": "footnote",
      "label": "f8",
      "text": "Monitoring of F- only applies if fluorine compounds are used in the processes."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2020/2009/annex/division/1/division/1.1/division/1.1.9/division/1.1.9.3/division/BAT",
    "retrieved_at": "2026-11-01T15:12:03.527850+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}