OpenLegislation

Division BAT 29 In order to reduce VOC emissions from publication rotogravure printing, BAT is to use a toluene recovery system based on adsorption and one or both of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescription
(a)Use of retention inksRetention inks slow the formation of the dried film surface, which allows toluene to evaporate over a longer time and therefore more toluene to be released in the dryer and recovered by the toluene recovery system.
(b)Automatic cleaning systems connected to the toluene recovery systemAutomated cylinder cleaning with air extraction to the toluene recovery system.

Table 31

BAT-associated emission level (BAT-AEL) for fugitive emissions of VOCs from publication rotogravure printing

ParameterUnitBAT-AEL(Yearly average)
Fugitive VOC emissions as calculated by the solvent mass balancePercentage (%) of the solvent input< 2,5

The associated monitoring is given in BAT 10.

Table 32

BAT-associated emission level (BAT-AEL) for VOC emissions in waste gases from publication rotogravure printing

ParameterUnitBAT-AEL(Daily average or average over the sampling period)
TVOCmg C/Nm3 10–20

The associated monitoring is given in BAT 11.