# Commission Implementing Decision (EU) 2020/2009 of 22 June 2020 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for surface treatment using organic solvents including preservation of wood and wood products with chemicals (notified under document C(2020) 4050) (Text with EEA relevance), Division 1.6: BAT conclusions for coil coating

Extent: E+W+S+N.I.

The emission levels for coil coating given below are associated with the general BAT conclusions given in Section 1.1.
Table 14
BAT-associated emission level (BAT-AEL) for fugitive emissions of VOCs from coil coating
Parameter
Unit
BAT-AEL(Yearly average)
Fugitive VOC emissions as calculated by the solvent mass balance
Percentage (%) of the solvent input
< 1–3
The associated monitoring is given in BAT 10.
Table 15
BAT-associated emission level (BAT-AEL) for VOC emissions in waste gases from coil coating
The upper end of the BAT-AEL range is 50 mg C/Nm3 if techniques are used which allow the reuse/recycling of the recovered solvent.
For plants using BAT 16 (c) in combination with an off-gas treatment technique, an additional BAT-AEL of less than 50 mg C/Nm3 applies to the waste gas of the concentrator.
Parameter
Unit
BAT-AEL(Daily average or average over the sampling period)
TVOC
mg C/Nm3
1–20
The associated monitoring is given in BAT 11.

---
Source: https://www.legislation.gov.uk/eudn/2020/2009/annex/division/1/division/1.6 (the official version)
Page: https://openlegislation.uk/eu-decision-2020-2009/annex/division-1/division-1.6
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.