  "url": "https://openlegislation.uk/eu-decision-2020-2009/annex/division-2/division-2.10/division-BAT",
  "json_url": "https://openlegislation.uk/eu-decision-2020-2009/annex/division-2/division-2.10/division-BAT.json",
  "legislation": "eudn/2020/2009",
  "legislation_title": "Commission Implementing Decision (EU) 2020/2009 of 22 June 2020 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for surface treatment using organic solvents including preservation of wood and wood products with chemicals (notified under document C(2020) 4050) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2020-2009",
  "path": "annex/division/2/division/2.10/division/BAT",
  "kind": "division",
  "number": "BAT 46",
  "heading": "In order to prevent or reduce emissions to soil and groundwater, BAT is to use all of the techniques given below.",
  "text": "Technique\nDescription\n(a)\nPlant and equipment containment or bund\nThe parts of the plant in which treatment chemicals are stored or handled, i.e. treatment chemicals storage area, treatment, post-treatment conditioning and interim storage areas (comprising treatment vessel, working vessel, unloading/pull-out facilities, dripping/drying area, cooling zone), pipes and ductwork for treatment chemicals, and creosote (re)conditioning facilities, are contained or bunded. Containments and bunds have impermeable surfaces, are resistant to treatment chemicals and have sufficient capacity to capture and hold the volumes handled or stored in the plant/equipment.\nDrip trays (made of treatment-chemical-resistant material) may also be used as local containments for the collection and recovery of drips and spills of treatment chemicals from critical equipment or processes (i.e. valves, inlets/outlets of storage tanks, treatment vessels, working tanks, unloading/pull-out zones, handling of freshly treated wood, cooling/drying zone).\nThe liquids in the containments/bunds and drip trays are collected to recover the treatment chemicals for their reuse in the treatment chemicals system. Sludge generated in the collection system is disposed of as hazardous waste.\n(b)\nImpermeable floors\nFloors of areas which are not contained or bunded, and where drips, spills, accidental releases or leaching of treatment chemicals may occur are impermeable to the substances concerned (e.g. storage of treated wood on impermeable floors in the event that it is required in the BPR authorisation for the wood preservative used for the treatment). The liquids on the floors are collected to recover the treatment chemicals for their reuse in the treatment chemicals system. Sludge generated in the collection system is disposed of as hazardous waste.\n(c)\nWarning systems for equipment identified as ‘critical’\n‘Critical’ equipment (see BAT 30) is equipped with warning systems to indicate malfunctions.\n(d)\nPrevention and detection of leaks from underground storage and ductwork for harmful/hazardous substances and record-keeping\nThe use of underground components is minimised. When underground components are used for the storage of harmful/hazardous substances, secondary containment (e.g. double-walled containment) is put in place. Underground components are equipped with leak detection devices.\nRisk-based and regular monitoring of underground storage and ductwork is carried out to identify potential leakages; when necessary, leaking equipment is repaired. A record is kept of incidents that may cause soil and/or groundwater pollution.\n(e)\nRegular inspection and maintenance of plant and equipment\nThe plant and the equipment are regularly inspected and serviced to ensure proper functioning; this includes in particular checking the integrity and/or leak-free status of valves, pumps, pipes, tanks, pressure vessels, drip trays, and containments/bunds and the proper functioning of warning systems.\n(f)\nTechniques to prevent cross-contamination\nCross-contamination (i.e. the contamination of plant areas that usually do not come into contact with treatment chemicals) is prevented by using appropriate techniques such as:\ndesign of drip trays in such a way that forklifts are not in contact with potentially contaminated surfaces of the drip trays;\ndesign of charging equipment (used to remove treated wood from the treatment vessel) in such a way that the carry-over of treatment chemicals is prevented;\nuse of a crane system for handling treated wood;\nuse of dedicated transport vehicles for potentially contaminated areas;\nrestricted access to potentially contaminated areas;\nuse of grit walkways.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2020/2009/annex/division/2/division/2.10/division/BAT",
    "retrieved_at": "2026-11-01T15:12:03.527850+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}