OpenLegislation

Division BAT 52 In order to reduce NOX emissions in waste gases while limiting CO emissions from the thermal treatment of off-gases in wood and wood products preservation using creosote and/or solvent-based treatment chemicals, BAT is to use technique (a) or both of the techniques given below.

United Kingdom

Original text. Later amendments are not shown.

TechniqueDescriptionApplicability
(a)

Optimisation of thermal treatment conditions

(design and operation)

See BAT 17 (a).Design applicability may be restricted for existing plants.
(b)Use of low-NOX burnersSee BAT 17 (b).Applicability may be restricted at existing plants by design and/or operational constraints.

Table 37

BAT-associated emission level (BAT-AEL) for NOX emissions in waste gases and indicative emission level for CO emissions in waste gases to air from the thermal treatment of off-gases in wood and wood products preservation using creosote and/or solvent-based treatment chemicals

The BAT-AEL and indicative level do not apply where off-gases are sent to a combustion plant.

ParameterUnitBAT-AELf1(Average over the sampling period)Indicative emission level(Average over the sampling period)
NOX mg/Nm3 20–130No indicative level
CONo BAT-AEL20–150

The associated monitoring is given in BAT 45.

Annotations

Footnotes

f1

The BAT-AEL and indicative level do not apply where off-gases are sent to a combustion plant.