Division BAT 52 In order to reduce NOX emissions in waste gases while limiting CO emissions from the thermal treatment of off-gases in wood and wood products preservation using creosote and/or solvent-based treatment chemicals, BAT is to use technique (a) or both of the techniques given below.
United Kingdom
| Technique | Description | Applicability | |
|---|---|---|---|
| (a) | Optimisation of thermal treatment conditions (design and operation) | See BAT 17 (a). | Design applicability may be restricted for existing plants. |
| (b) | Use of low-NOX burners | See BAT 17 (b). | Applicability may be restricted at existing plants by design and/or operational constraints. |
Table 37
BAT-associated emission level (BAT-AEL) for NOX emissions in waste gases and indicative emission level for CO emissions in waste gases to air from the thermal treatment of off-gases in wood and wood products preservation using creosote and/or solvent-based treatment chemicals
| The BAT-AEL and indicative level do not apply where off-gases are sent to a combustion plant. | |||
| Parameter | Unit | BAT-AELf1(Average over the sampling period) | Indicative emission level(Average over the sampling period) |
|---|---|---|---|
| NOX | mg/Nm3 | 20–130 | No indicative level |
| CO | No BAT-AEL | 20–150 | |
The associated monitoring is given in BAT 45.
Annotations
Footnotes
- f1
-
The BAT-AEL and indicative level do not apply where off-gases are sent to a combustion plant.