OpenLegislation

Division BAT 45 BAT is to monitor emissions in waste gases with a frequency of at least once every year and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.

United Kingdom

Original text. Later amendments are not shown.

To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions.

This includes: acenaphthene, acenaphthylene, anthracene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(g,h,i)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, fluoranthene, fluorene, indeno(1,2,3-cd)pyrene, naphthalene, phenanthrene and pyrene.

The monitoring only applies to emissions from the thermal treatment of off-gases.

ParameterProcessStandard(s)Monitoring associated with
TVOCf1 Wood and wood products preservation using creosote and solvent-based treatment chemicalsEN 12619BAT 49, BAT 51
PAHs f2 Wood and wood products preservation using creosoteNo EN standard availableBAT 51
NOX f3 Wood and wood products preservation using creosote and solvent-based treatment chemicalsEN 14792BAT 52
CO EN 15058

Annotations

Footnotes

f1

To the extent possible, the measurements are carried out at the highest expected emission state under normal operating conditions.

f2

This includes: acenaphthene, acenaphthylene, anthracene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(g,h,i)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, fluoranthene, fluorene, indeno(1,2,3-cd)pyrene, naphthalene, phenanthrene and pyrene.

f3

The monitoring only applies to emissions from the thermal treatment of off-gases.