# Council Directive of 20 May 1975 on the approximation of the laws of the Member States relating to aerosol dispensers (75/324/EEC), Division 6.2.1: Test on unfilled containers

Extent: E+W+S+N.I.

The test pressure shall be applied for 25 seconds on five containers selected at random from a homogeneous batch of 2 500 unfilled containers, i.e. manufactured from the same materials by the same continuous batch manufacturing process, or from a batch constituting one hour's production.
If any one of these containers does not pass the test, ten additional containers shall be drawn at random from the same batch and put through the same test.
If any one of these aerosol containers does not pass the test, the whole batch shall be unsuitable for use.

---
Source: https://www.legislation.gov.uk/eudr/1975/324/annex/division/6/division/6.2/division/6.2.1 (the official version)
Page: https://openlegislation.uk/eu-directive-1975-324/annex/division-6/division-6.2/division-6.2.1
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.