OpenLegislation

Division 6.3.1.3.1.4 Each aerosol dispenser is to be tested:F1

United Kingdom

Original text. Later amendments are not shown.

  1. (a)

    when full according to the complete procedure, with the gas burner in the range of 15-90 cm distance from the actuator of the aerosol can;

  2. (b)

    when 10-12 % full nominal (% by mass) only one test, either at 15 cm distance from the actuator when the spray from a full can did not ignite at all, or at the flame ignition distance of the spray of a full can plus 15 cm.

Annotations

Textual amendments

F1

Inserted by Commission Directive 2008/47/EC of 8 April 2008 amending, for the purposes of adapting to technical progress, Council Directive 75/324/EEC on the approximation of the laws of the Member States relating to aerosol dispensers (Text with EEA relevance).