Division 6.1.6
United Kingdom
The end-point should be reached at the end of three minutes from when the solution started to boil. The final titre, Vo, shall be between 39·0 and 41·0 ml. If Vo lies outside these limits, adjust the copper concentration of Fehling's solution A (4.1.1) and repeat the standardization process.