OpenLegislation

Division 2 Sampling at the point of compliance shall meet the following requirements:F1

United Kingdom

Original text. Later amendments are not shown.

  1. (a)

    compliance samples for certain chemical parameters (in particular copper, lead and nickel) shall be taken at the consumer's tap without prior flushing. A random daytime sample of one litre volume is to be taken. As an alternative, Member States may use fixed stagnation time methods that better reflect their national situation, provided that, at the supply zone level, this does not result in fewer cases of non-compliance than using the random daytime method;

  2. (b)

    compliance samples for microbiological parameters at the point of compliance shall be taken and handled according to EN ISO 19458, sampling purpose B.

Annotations

Textual amendments

F1