Division 8 Temporary storage of metallic mercuryF1
United Kingdom
For the purposes of temporary storage for more than 1 year of metallic mercury, the following requirements shall apply:
-
Metallic mercury shall be stored separately from other waste.
-
Containers shall be stored in collecting basins suitably coated so as to be free of cracks and gaps and impervious to metallic mercury with a containment volume adequate for the quantity of mercury stored.
-
The storage site shall be provided with engineered or natural barriers that are adequate to protect the environment against mercury emissions and a containment volume adequate for the total quantity of mercury stored.
-
The storage site floors shall be covered with mercury-resistant sealants. A slope with a collection sump shall be provided.
-
The storage site shall be equipped with a fire protection system.
-
Storage shall be arranged in a way to ensure that all containers are easily retrievable.