Division 2 Sites for treatment:

United Kingdom

Original text. Later amendments are not shown.

  • impermeable surfaces for appropriate areas with the provision of spillage collection facilities, decanters and cleanser-degreasers,

  • appropriate storage for dismantled spare parts, including impermeable storage for oil-contaminated spare parts,

  • appropriate containers for storage of batteries (with electrolyte neutralisation on site or elsewhere), filters and PCB/PCT-containing condensers,

  • appropriate storage tanks for the segregated storage of end-of-life vehicle fluids: fuel, motor oil, gearbox oil, transmission oil, hydraulic oil, cooling liquids, antifreeze, brake fluids, battery acids, air-conditioning system fluids and any other fluid contained in the end-of-life vehicle,

  • equipment for the treatment of water, including rainwater, in compliance with health and environmental regulations,

  • appropriate storage for used tyres, including the prevention of fire hazards and excessive stockpiling.