Division 5.2.5.1 Study Reports of Controlled Clinical Studies Pertinent to the Claimed IndicationF1
United Kingdom
In general, clinical trials shall be done as ‘ controlled clinical trials ’ if possible, randomised and as appropriate versus placebo and versus an established medicinal product of proven therapeutic value; any other design shall be justified. The treatment of the control groups will vary from case to case and also will depend on ethical considerations and therapeutic area; thus it may, in some instances, be more pertinent to compare the efficacy of a new medicinal product with that of an established medicinal product of proven therapeutic value rather than with the effect of a placebo.
- (1)
As far as possible, and particularly in trials where the effect of the product cannot be objectively measured, steps shall be taken to avoid bias, including methods of randomisation and blinding.
- (2)
The protocol of the trial must include a thorough description of the statistical methods to be employed, the number and reasons for inclusion of patients (including calculations of the power of the trial), the level of significance to be used and a description of the statistical unit. Measures taken to avoid bias, particularly methods of randomisation, shall be documented. Inclusion of a large number of subjects in a trial must not be regarded as an adequate substitute for a properly controlled trial.
The safety data shall be reviewed taking into account guidelines published by the Commission, with particular attention to events resulting in changes of dose or need for concomitant medication, serious adverse events, events resulting in withdrawal, and deaths. Any patients or patient groups at increased risk shall be identified and particular attention paid to potentially vulnerable patients who may be present in small numbers, e.g., children, pregnant women, frail elderly, people with marked abnormalities of metabolism or excretion etc. The implication of the safety evaluation for the possible uses of the medicinal product shall be described.