Division 2 The height (Bh) of transverse and longitudinal bulkheads/barriers shall be not less than (8 × hw) metres, where hw is the height of the accumulated water as calculated by application of the residual freeboard and significant wave height ( as referred to in paragraphs 1.1 and 1.3). However in no case is the height of the bulkhead/barrier to be less than the greater of:
United Kingdom
- (a)
2,2 metres; or
- (b)
the height between the bulkhead deck and the lower point of the underside structure of the intermediate or hanging car decks, when these are in their lowered position. It should be noted that any gaps between the top edge of the bulkhead and the underside of the plating must be ‘plated-in’ in the transverse or longitudinal direction as appropriate (see figure 6).
Bulkheads/barriers with a height less than that specified above, may be accepted if model tests are carried out in accordance with part II of this Annex to confirm that the alternative design ensures appropriate standard of survivability. Care needs to be taken when fixing the height of the bulkhead/barrier such that the height shall also be sufficient to prevent progressive flooding within the required stability range. This range is not to be prejudiced by model tests.
Note: The range may be reduced to 10 degrees provided the corresponding area under the curve is increased (as referred to in MSC 64/22).