Division 1.2.1
ESAs may comply with the requirements of any combination of the following test methods at the manufacturer's discretion provided that this results in the full frequency range specified in paragraph 3.1 of this Annex being covered.
-
Absorber chamber test: according to ISO DIS 11452-2: 2003
-
TEM cell testing: according to ISO 11452-3: 3rd edition 2001
-
Bulk current injection testing: according to ISO DIS 11452-4: 2003
-
Stripline testing: according to ISO 11452-5: 2nd edition 2002
-
800 mm stripline: according to paragraph 4.5 of this Annex
(Frequency range and general test conditions shall be based on ISO DIS 11452-1: 2003).