# Commission Directive 2005/62/EC of 30 September 2005 implementing Directive 2002/98/EC of the European Parliament and of the Council as regards Community standards and specifications relating to a quality system for blood establishments (Text with EEA relevance), Division 3

Extent: E+W+S+N.I.

There shall be clearly defined procedures to resolve discrepant results and ensure that blood and blood components that have a repeatedly reactive result in a serological screening test for infection with the viruses mentioned in Annex IV to Directive 2002/98/EC shall be excluded from therapeutic use and be stored separately in a dedicated environment. Appropriate confirmatory testing shall take place. In case of confirmed positive results, appropriate donor management shall take place including the provision of information to the donor and follow-up procedures.

---