OpenLegislation

Division 1.4.2.2 Interlocking movable guards

United Kingdom

Original text. Later amendments are not shown.

Interlocking movable guards must:

  • as far as possible remain attached to the machinery when open,

  • be designed and constructed in such a way that they can be adjusted only by means of an intentional action.

Interlocking movable guards must be associated with an interlocking device that:

  • prevents the start of hazardous machinery functions until they are closed and

  • gives a stop command whenever they are no longer closed.

Where it is possible for an operator to reach the danger zone before the risk due to the hazardous machinery functions has ceased, movable guards must be associated with a guard locking device in addition to an interlocking device that:

  • prevents the start of hazardous machinery functions until the guard is closed and locked, and

  • keeps the guard closed and locked until the risk of injury from the hazardous machinery functions has ceased.

Interlocking movable guards must be designed in such a way that the absence or failure of one of their components prevents starting or stops the hazardous machinery functions.