Division 2 The titles of the tables are indicative:
United Kingdom
-
Table I A presents minimum requirements for laboratory activities.
-
Table I B presents additions to and modifications of Table I A for glasshouse/growth-room activities involving GMMs.
-
Table I C presents additions to and modifications of Table I A for activities with animals involving GMMs.
-
Table II presents minimum requirements for activities other than laboratory activities.
In some particular cases, it might be necessary to apply a combination of measures, from Table I A and Table II, of the same level.
In some cases users may, with the agreement of the competent authority, not apply a specification under a particular containment level or combine specifications from two different levels.
In these tables ‘optional’ means that the user may apply these measures on a case-by-case basis, subject to the assessment referred to in Article 4(2).
Notes on Division CONTAINMENT AND OTHER PROTECTIVE MEASURES
Footnotes
- f1
- Isolation
the laboratory is separated from other areas in the same building or is in a separate building.
- f2
- Airlock
entry must be through an airlock which is a chamber isolated from the laboratory. The clean side of the airlock must be separated from the restricted side by changing or showering facilities and preferably by interlocking doors.
- f3
-
Activities where transmission does not occur via airborne route.
- f4
- HEPA
High efficiency particulate air.
- f5
-
Where viruses which are not retained by HEPA filters are used, extra requirements will be necessary for extract air.
- f6
-
With validated procedures, allowing the safe transfer of material into an autoclave outside the lab, and providing an equivalent level of protection.
- f7
-
The glasshouse shall consist of a permanent structure with a continuous waterproof covering, located on a site graded to prevent entry of surface-water run-off, and with self-closing lockable doors.
- f8
-
Where transmission can occur through the ground.
- f9
- Animal unit
a building or separate area within a building containing facilities and other areas such as changing rooms, showers, autoclaves, food storage areas, etc.
- f10
- Animal facility
a facility normally used to house stock, breeding or experimental animals or one which is used for the performance of minor surgical procedures.
- f11
- Isolators