OpenLegislation

Division 2 The titles of the tables are indicative:

United Kingdom

Original text. Later amendments are not shown.

  • Table I A presents minimum requirements for laboratory activities.

  • Table I B presents additions to and modifications of Table I A for glasshouse/growth-room activities involving GMMs.

  • Table I C presents additions to and modifications of Table I A for activities with animals involving GMMs.

  • Table II presents minimum requirements for activities other than laboratory activities.

In some particular cases, it might be necessary to apply a combination of measures, from Table I A and Table II, of the same level.

In some cases users may, with the agreement of the competent authority, not apply a specification under a particular containment level or combine specifications from two different levels.

In these tables ‘optional’ means that the user may apply these measures on a case-by-case basis, subject to the assessment referred to in Article 4(2).

Notes on Division CONTAINMENT AND OTHER PROTECTIVE MEASURES

Footnotes

f1
Isolation
  • the laboratory is separated from other areas in the same building or is in a separate building.

  • f2
    Airlock
  • entry must be through an airlock which is a chamber isolated from the laboratory. The clean side of the airlock must be separated from the restricted side by changing or showering facilities and preferably by interlocking doors.

  • f3

    Activities where transmission does not occur via airborne route.

    f4
    HEPA
  • High efficiency particulate air.

  • f5

    Where viruses which are not retained by HEPA filters are used, extra requirements will be necessary for extract air.

    f6

    With validated procedures, allowing the safe transfer of material into an autoclave outside the lab, and providing an equivalent level of protection.

    f7

    The glasshouse shall consist of a permanent structure with a continuous waterproof covering, located on a site graded to prevent entry of surface-water run-off, and with self-closing lockable doors.

    f8

    Where transmission can occur through the ground.

    f9
    Animal unit
  • a building or separate area within a building containing facilities and other areas such as changing rooms, showers, autoclaves, food storage areas, etc.

  • f10
    Animal facility
  • a facility normally used to house stock, breeding or experimental animals or one which is used for the performance of minor surgical procedures.

  • f11
    Isolators
  • transparent boxes where small animals are contained within or outside a cage; for large animals, isolated rooms may be more appropriate.