OpenLegislation

Division .5 Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank, having a capacity of 500 litres or above, situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. In the special case of deep tanks situated in any shaft or pipe tunnel or similar space, valves on the tank shall be fitted but control in the event of fire may be effected by means of an additional valve on the pipe or pipes outside the tunnel or similar space. If such additional valve is fitted in the machinery space it shall be operated from a position outside this space.F1

United Kingdom

Original text. Later amendments are not shown.

  1. .1

    In ships constructed on or after 1 January 2003 the controls for remote operation of the valve for the emergency generator fuel tank shall be in a separate location from the controls for remote operation of other valves located in machinery spaces.

  2. .2

    In ships constructed on or after 1 January 2012 having a gross tonnage of less than 500 , fuel tanks above the double bottom shall be fitted with a cock or valve.

  3. .3

    In ships constructed before 1 January 2012 having a gross tonnage of less than 500 the cock or the valve mentioned in the first paragraph shall also be fitted in fuel tanks having a capacity of less than 500 litres and situated above the double bottom, not later than the first periodical survey on or after 1 January 2012 .

Annotations

Textual amendments

F1

Substituted by Commission Directive 2010/36/EU of 1 June 2010 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance).