Division .5 Periodically unattended machinery spacesF1
United Kingdom
In addition to the requirements of provisions 1 to 4, the oil fuel and lubricating oil systems shall comply with the following:
- .1
where daily service oil fuel tanks are filled automatically, or by remote control, means shall be provided to prevent overflow spillages. Other equipment which treats flammable liquids automatically, e.g. oil fuel purifiers, which, whenever practicable, shall be installed in a special space reserved for purifiers and their heaters, shall have arrangements to prevent overflow spillages;
- .2
where daily service oil fuel tanks or settling tanks are fitted with heating arrangements, a high temperature alarm shall be provided if the flashpoint of the oil fuel can be exceeded.