  "text": "Rooms containing furniture and furnishings of restricted fire risk are, for the purpose of Regulation II-2/B/4, those rooms containing furniture and furnishings of restricted fire risk (whether cabins, public spaces, offices and other types of accommodation) in which:\n.1 all case furniture such as desks, wardrobes, dressing tables, bureaux, dressers, is constructed entirely of approved non-combustible materials, except that a combustible veneer not exceeding 2 mm may be used on the working surface of such articles;\n.2 all free-standing furniture such as chairs, sofas, tables, is constructed with frames of non-combustible materials;\n.3 all draperies, curtains and other suspended textile materials have qualities of resistance to the propagation of flame not inferior to those of wool of mass 0,8 kg/m 2 , in accordance with IMO Resolution A.471(XII), as amended.\nFor class B, C and D ships constructed on or after 1 January 2003 , ‘ IMO Resolution A.471(XII) ’ , as amended, shall read ‘ Fire Test Procedures Code ’ ;\n.4 all floor coverings have qualities of resistance to the propagation of flame not inferior to those of an equivalent woollen material used for the same purpose.\nFor class B, C and D ships constructed on or after 1 January 2003 , this subparagraph shall read:\nall floor coverings have low flame spread characteristics;\n.5 all exposed surfaces of bulkheads, linings and ceilings have low flame-spread characteristics; and\n.6 all upholstered furniture has qualities of resistance to the ignition and propagation of flame in accordance with the Fire Test Procedures of Upholstered Furniture of IMO Resolution A.652(16)\nFor class B, C and D ships constructed on or after 1 January 2003 , ‘ IMO Resolution A.652(16) ’ shall read ‘ Fire Test Procedures Code ’ .\nFOR CLASS B, C AND D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2003\n.7 all bedding components have qualities of resistance to the ignition and propagation of flame, this being determined in accordance with the Fire Test Procedures Code.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Substituted by Commission Directive 2010/36/EU of 1 June 2010 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudr/2009/45/annex/I/chapter/3/part/A/division/2/division/1/division/.22",
    "retrieved_at": "2026-11-01T15:22:12.497948+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}