The total volume of combustible facings, mouldings, decorations and veneers in any accommodation and service space shall not exceed a volume equivalent to 2,5 mm veneer on the combined area of the walls and ceilings. Furniture fixed to linings, bulkheads or decks need not be included in the calculation of the total volume of combustible materials.

In the case of ships fitted with an automatic sprinkler system complying with the provisions of Regulation II 2-A/8, the above volume may include some combustible material used for erection of ‘ C ’ class divisions.