OpenLegislation

Division .2 Structural protectionF1

United Kingdom

Original text. Later amendments are not shown.

  1. .1In new ships carrying more than 36 passengers the boundary bulkheads and decks of special category spaces shall be insulated to ‘A-60’ class standard. However, where an open deck space (as defined in Regulation II-2/B/4.2.2(5)), a sanitary or similar space (as defined in Regulation II-2/B/4.2.2(9)) or a tank, void or auxiliary machinery space having little or no fire risk (as defined in Regulation II-2/B/4.2.2(10)), is on one side of the division the standard may be reduced to ‘A-0’.
  2. .2Division .2
  3. .3Indicators shall be provided on the navigating bridge which shall indicate when any fire door leading to or from the special category spaces is closed.

Annotations

Textual amendments

F1

Substituted by Commission Directive 2010/36/EU of 1 June 2010 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance).