Division .5b Portable extinguishers shall be provided at each deck level in each hold or compartment where vehicles are carried, spaced not more than 20 metres apart on both sides of the space. At least one portable fire extinguisher shall be located at each access to such space.F1

United Kingdom

Original text. Later amendments are not shown.

In addition the following fire extinguishing appliances shall be provided in special category spaces:

  1. .1

    at least three water-fog applicators; and

  2. .2

    one portable foam applicator unit complying with the provisions of the Fire Safety Systems Code, provided that at least two such units are available in the ship for use in such ro-ro space.