OpenLegislation

Division .7.1 For reasons of noise reduction, the Administration may approve, as an equivalent, doors with built-in ventilation sound-locks with openings at the bottom on one side of the door and at the top on the other side, on condition that the following provisions have been complied with:F1

United Kingdom

Original text. Later amendments are not shown.

  1. .1

    The upper opening shall always face towards the corridor and shall be provided with a grating of non-combustible material and an automatically operating fire damper, which is activated at a temperature of about 70 °C.

  2. .2

    The lower opening shall be provided with a grating made of a non-combustible material.

  3. .3

    The doors shall be tested in accordance with Resolution A.754(18).

Annotations

Textual amendments

F1

Substituted by Commission Directive 2010/36/EU of 1 June 2010 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance).