  "url": "https://openlegislation.uk/eu-directive-2009-45/annex-I/chapter-3/part-B/division-9/division-.2/division-1/division-.3",
  "json_url": "https://openlegislation.uk/eu-directive-2009-45/annex-I/chapter-3/part-B/division-9/division-.2/division-1/division-.3.json",
  "legislation": "eudr/2009/45",
  "legislation_title": "Directive 2009/45/EC of the European Parliament and of the Council of 6 May 2009 on safety rules and standards for passenger ships (Recast) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-directive-2009-45",
  "path": "annex/I/chapter/3/part/B/division/9/division/.2/division/1/division/.3",
  "kind": "division",
  "number": ".3",
  "heading": null,
  "text": "Ducts provided for the ventilation of machinery spaces, galleys, car deck spaces, ro-ro cargo spaces or special category spaces shall not pass through accommodation spaces, service spaces or control stations unless they comply with the conditions specified in subparagraphs .9.2.3.1.1 to .9.2.3.1.4 or .9.2.3.2.1 and .9.2.3.2.2:\n.1.1 the ducts are constructed of steel having a thickness of at least 3 mm and 5 mm for ducts the widths or diameters of which are up to and including 300 mm and 760 mm and over respectively and, in the case of such ducts, the widths or diameters of which are between 300 mm and 760 mm having a thickness to be obtained by interpolation;\n.1.2 the ducts are suitably supported and stiffened;\n.1.3 the ducts are fitted with automatic fire dampers close to the boundaries penetrated; and\n.1.4 the ducts are insulated to ‘ A-60 ’ standard from the machinery spaces, galleys, car deck spaces, ro-ro cargo spaces or special category spaces to a point at least 5 metres beyond each fire damper;\nor\n.2.1 the ducts are constructed of steel in accordance with paragraphs .9.2.3.1.1 and .9.2.3.1.2; and\n.2.2 the ducts are insulated to ‘ A-60 ’ standard throughout the accommodation spaces, service spaces or control stations;\nexcept that penetrations of main zone divisions shall also comply with the requirements of subparagraph .9.2.8.\nIn new class B, C and D ships constructed on or after 1 January 2003 , the ventilation systems for machinery spaces of category A, vehicle spaces, ro-ro spaces, galleys, special category spaces and cargo spaces shall, in general, be separated from each other and from the ventilation systems serving other spaces. Except that the galley ventilation systems on passenger ships carrying not more than 36 passengers need not be completely separated, but may be served by separate ducts from a ventilation unit serving other spaces. In any case an automatic fire damper shall be fitted in the galley ventilation duct near the ventilation unit.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Substituted by Commission Directive 2010/36/EU of 1 June 2010 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (Text with EEA relevance)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudr/2009/45/annex/I/chapter/3/part/B/division/9/division/.2/division/1/division/.3",
    "retrieved_at": "2026-11-01T15:22:12.497948+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}