Where they pass through accommodation spaces or spaces containing combustible materials, the exhaust ducts from galley ranges shall be constructed of ‘ A ’ class divisions. Each exhaust duct shall be fitted with:

  1. .1

    a grease trap readily removable for cleaning;

  2. .2

    a fire damper located in the lower end of the duct;

  3. .3

    arrangements, operable from within the galley, for shutting off the exhaust fans; and

  4. .4

    fixed means for extinguishing a fire within the duct.