# Directive 2009/45/EC of the European Parliament and of the Council of 6 May 2009 on safety rules and standards for passenger ships (Recast) (Text with EEA relevance), Division .4: As permitted by paragraphs .2.2 and .2.3 ducts shall be either:

Extent: E+W+S+N.I.

.1.1 constructed of steel having a thickness of at least 3 mm for ducts with a free cross-sectional area of less than 0,075 m 2 , at least 4 mm for ducts with a free cross-sectional area of between 0,075 m 2 and 0,45 m 2 , and at least 5 mm for ducts with a free cross-sectional area of over 0,45 m 2 ;
.1.2 suitably supported and stiffened;
.1.3 fitted with automatic fire dampers close to the boundaries penetrated; and
.1.4 insulated to ‘ A-60 ’ class standard from the boundaries of the spaces they serve to a point at least 5 m beyond each fire damper;
or
.2.1 constructed of steel in accordance with paragraphs .2.4.1.1 and .2.4.1.2; and
.2.2 insulated to ‘ A-60 ’ class standard throughout the spaces they pass through, except for ducts that pass through spaces of category (9) or (10) as defined in Regulation II-2/B/4.2.2.

---