# Directive 2009/45/EC of the European Parliament and of the Council of 6 May 2009 on safety rules and standards for passenger ships (Recast) (Text with EEA relevance), Division .7: Ventilation systems for laundries in passenger ships carrying more than 36 passengers

Extent: E+W+S+N.I.

Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B/4.2.2 shall be fitted with:
.1 filters readily removable for cleaning purposes;
.2 a fire damper located in the lower end of the duct which is automatically and remotely operated;
.3 remote-control arrangements for shutting off the exhaust fans and supply fans from within the space and for operating the fire damper mentioned in paragraph .7.2; and
.4 suitably located hatches for inspection and cleaning.

---
Source: https://www.legislation.gov.uk/eudr/2009/45/annex/I/chapter/3/part/B/division/9a/division/1/division/.7 (the official version)
Page: https://openlegislation.uk/eu-directive-2009-45/annex-I/chapter-3/part-B/division-9a/division-1/division-.7
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.