# Directive 2010/75/EU of the European Parliament and of the Council of 24 November 2010 on industrial emissions (integrated pollution prevention and control) (Recast) (Text with EEA relevance), Division 2.1

Extent: E+W+S+N.I.

The following measurements relating to air polluting substances shall be carried out:
(a) continuous measurements of the following substances: NOx, provided that emission limit values are set, CO, total dust, TOC, HCl, HF, SO2;
(b) continuous measurements of the following process operation parameters: temperature near the inner wall or at another representative point of the combustion chamber as authorised by the competent authority, concentration of oxygen, pressure, temperature and water vapour content of the waste gas;
(c) at least two measurements per year of heavy metals and dioxins and furans; one measurement at least every 3 months shall, however, be carried out for the first 12 months of operation.

---
Source: https://www.legislation.gov.uk/eudr/2010/75/annex/VI/part/6/division/2/division/2.1 (the official version)
Page: https://openlegislation.uk/eu-directive-2010-75/annex-VI/part-6/division-2/division-2.1
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.