# Directive 2010/75/EU of the European Parliament and of the Council of 24 November 2010 on industrial emissions (integrated pollution prevention and control) (Recast) (Text with EEA relevance), Part 7: Formula to calculate the emission concentration at the standard percentage oxygen concentration

Extent: E+W+S+N.I.

E S = 21 – O S 21 – O M × E M
ES calculated emission concentration at the standard percentage oxygen concentration
EM measured emission concentration
OS standard oxygen concentration
OM measured oxygen concentration

---
Source: https://www.legislation.gov.uk/eudr/2010/75/annex/VI/part/7 (the official version)
Page: https://openlegislation.uk/eu-directive-2010-75/annex-VI/part-7