Division 1 The manufacturer must assign fireworks to different categories according to Article 6 characterised by net explosive content, safety distances, noise level, or similar. The category must be clearly indicated on the label.
United Kingdom
- (a)
For category F1 fireworks, the following conditions must be met:
- (i)
the safety distance must be at least 1 m. However, where appropriate the safety distance may be less,
- (ii)
the maximum noise level must not exceed 120 dB (A, imp), or an equivalent noise level as measured by another appropriate method, at the safety distance,
- (iii)
category F1 must not comprise bangers, banger batteries, flash bangers and flash banger batteries,
- (iv)
throwdowns in category F1 must not contain more than 2,5 mg silver fulminate.
- (i)
- (b)
For category F2 fireworks, the following conditions must be met:
- (i)
the safety distance must be at least 8 m. However, where appropriate the safety distance may be less,
- (ii)
the maximum noise level must not exceed 120 dB (A, imp), or an equivalent noise level as measured by another appropriate method, at the safety distance.
- (i)
- (c)
For category F3 fireworks, the following conditions must be met:
- (i)
the safety distance must be at least 15 m. However, where appropriate the safety distance may be less,
- (ii)
the maximum noise level must not exceed 120 dB (A, imp), or an equivalent noise level as measured by another appropriate method, at the safety distance.
- (i)