OpenLegislation

Division 3.3 Detonators (including delay detonators) and relays shall also comply with the following requirements:

United Kingdom

Original text. Later amendments are not shown.

  1. (a)

    detonators must reliably initiate the detonation of the blasting explosives which are intended to be used with them under all foreseeable conditions of use;

  2. (b)

    delay connectors for detonating cords must be reliably initiated;

  3. (c)

    the initiation capability must not be adversely affected by humidity;

  4. (d)

    the delay times of delay detonators must be sufficiently uniform to ensure that the probability of overlapping of the delay times of adjacent time steps is insignificant;

  5. (e)

    the electrical characteristics of electric detonators must be indicated on the packaging (e.g. no-fire current, resistance);

  6. (f)

    the wires of electric detonators must be of sufficient insulation and mechanical strength including the solidity of the link to the detonator, taking account of their intended use.