# Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (recast) (Text with EEA relevance), Division 1.1: The flowrate range

Extent: E+W+S+N.I.

The flowrate range is subject to the following conditions:
(i) the flowrate range of a measuring system shall be within the flowrate range of each of its elements, in particular the meter.
(ii) meter and measuring system:
Table 1
Specific measuring system
Characteristic of liquid
Minimum ratio of Qmax: Qmin
Fuel dispensers
Not Liquefied gases
10: 1
Liquefied gases
5: 1
Measuring system
Cryogenic liquids
5: 1
Measuring systems on pipeline and systems for loading ships
All liquids
Suitable for use
All other measuring systems
All liquids
4: 1

---