  "url": "https://openlegislation.uk/eu-directive-2014-32/annex-VII/division-3/division-7",
  "json_url": "https://openlegislation.uk/eu-directive-2014-32/annex-VII/division-3/division-7.json",
  "legislation": "eudr/2014/32",
  "legislation_title": "Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (recast) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-directive-2014-32",
  "path": "annex/VII/division/3/division/7",
  "kind": "division",
  "number": "7",
  "heading": "Putting into use",
  "text": "Table 5\nHowever, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers.\nNote: However, the manufacturer may specify a better accuracy for a certain type of measuring system.\nAccuracy Class\nTypes of Measuring system\n0,3\nMeasuring systems on pipeline\n0,5\nAll measuring systems if not differently stated elsewhere in this Table, in particular:\nfuel dispensers (not for liquefied gases),\nmeasuring systems on road tankers for liquids of low viscosity (< 20 mPa.s)\nmeasuring systems for (un)loading ships and rail and road tankers\nmeasuring systems for milk\nmeasuring systems for refuelling aircraft\n1,0\nMeasuring systems for liquefied gases under pressure measured at a temperature equal to or above – 10 °C\nMeasuring systems normally in class 0,3 or 0,5 but used for liquids\nwhose temperature is less than – 10 °C or greater than 50 °C\nwhose dynamic viscosity is higher than 1 000 mPa.s\nwhose maximum volumetric flowrate is not higher than 20 L/h\n1,5\nMeasuring systems for liquefied carbon dioxide\nMeasuring systems for liquefied gases under pressure measured at a temperature below – 10 °C (other than cryogenic liquids)\n2,5\nmeasuring systems for cryogenic liquids (temperature below – 153 °C)",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "However, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudr/2014/32/annex/VII/division/3/division/7",
    "retrieved_at": "2026-11-01T15:21:47.505881+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}