# Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (recast) (Text with EEA relevance), Division 4.2: Standard deviation

Extent: E+W+S+N.I.

Maximum permissible value for the standard deviation of a class X (x) instrument is the result of the multiplication of the factor (x) by the value in Table 2 below.
Table 2
Net Load (m)
Maximum permissible standard deviation for class X(1)
m ≤ 50 g
0,48 %
50 g < m ≤ 100 g
0,24 g
100 g < m ≤ 200 g
0,24 %
200 g < m ≤ 300 g
0,48 g
300 g < m ≤ 500 g
0,16 %
500 g < m ≤ 1 000 g
0,8 g
1 000 g < m ≤ 10 000 g
0,08 %
10 000 g < m ≤ 15 000 g
8 g
15 000 g < m
0,053 %
For class XI and XII (x) shall be less than 1.
For class XIII (x) shall be not greater than 1.
For class XIIII (x) shall be greater than 1.

---
Source: https://www.legislation.gov.uk/eudr/2014/32/annex/VIII/division/3/chapter/II/division/4/division/4.2 (the official version)
Page: https://openlegislation.uk/eu-directive-2014-32/annex-VIII/division-3/chapter-II/division-4/division-4.2