OpenLegislation

Appendix H Database for industrial source

United Kingdom

Original text. Later amendments are not shown.

This appendix presents a few examples for input values for some industrial noise sources that may be used to calculate industrial noise following the method described in 2.4 Industrial noise. As industrial noise sources are extremely specific for each industrial site, appropriate values are obtained from local, national or international databases or measurements as appropriate.

Table H-1

Coefficients LW, LW' and ΔLW,dir,xyz (x, y, z) for sound power

ΔLW,dir,xyz (x, y, z)=0

LW' is expressed as sound power per metre for line source, or per squared metre for area source.

DescriptionType of sourceSource directivity631252505001 0002 0004 0008 000
Grit blasting — outside — with nozzlePointSourceFreeField108,77110,37112,77107,77104,3798,0797,0786,97
Rotary kilnLineSourceFreeField79,2784,1786,6789,2793,0793,4792,0787,77
Ship yardAreaSourceHemiSpherical67,1769,0774,5762,1763,9766,7770,9768,07
Gas terminalAreaSourceHemiSpherical74,1770,0765,5764,1759,9757,7751,9756,07