154 The calibration function shall allow:
-
to automatically pair the motion sensor with the VU,
-
to digitally adapt the constant of the recording equipment (k) to the characteristic coefficient of the vehicle (w) (vehicles with two or more axle ratios shall be fitted with a switch device whereby these various ratios will automatically be brought into line with the ratio for which the equipment has been adapted to the vehicle),
-
to adjust (without limitation) the current time,
-
to adjust the current odometer value,
-
to update motion sensor identification data stored in the data memory,
-
to update or confirm other parameters known to the recording equipment: vehicle identification, w, l, tyre size and speed limiting device setting if applicable.
155 Pairing the motion sensor to the VU shall consist, at least, in:
-
updating motion sensor installation data held by the motion sensor (as needed),
-
copying from the motion sensor to the VU data memory necessary motion sensor identification data.
156 The calibration function shall be able to input necessary data through the calibration/downloading connector in accordance with the calibration protocol defined in Appendix 8. The calibration function may also input necessary data through other connectors.
Annotations
Textual amendments
- F1
- F2