Division 22 Performance characteristicsF1F2
United Kingdom
159 The Vehicle Unit shall be fully operational in the temperature range - 20 o C to 70 o C, and the motion sensor in the temperature range - 40 o C to 135 o C. Data memory content shall be preserved at temperatures down to - 40 o C.
160 The recording equipment shall be fully operational in the humidity range 10 % to 90 %.
161 The recording equipment shall be protected against over-voltage, inversion of its power supply polarity, and short circuits.
161a F3Motion sensors shall either:
-
react to a magnetic field which disturbs vehicle motion detection. In such circumstances, the vehicle unit will record and store a sensor fault (Requirement 070) or,
have a sensing element that is protected from, or immune to, magnetic fields.